Description
Fluke 87V MAX Specifications
Electrical Measurements
-
DC Voltage
Range: 0.1mV to 1000V
Accuracy: (0.05% + 1)
Resolution: 0.1mV -
AC Voltage (TrueRMS)
Range: 0.1mV to 1000V
Accuracy: (0.7% + 4)
Bandwidth: Up to 20kHz with low-pass filter (3dB @ 1kHz)
Resolution: 0.1mV -
DC Current
Range: 0.1A to 10A (20A for 30 seconds max)
Accuracy: (0.2% + 2)
Resolution: 0.1A -
AC Current (TrueRMS)
Range: 0.1A to 10A (20A for 30 seconds)
Accuracy: (1.0% + 2)
Resolution: 0.1A -
Resistance
Range: 0.1 to 50M
Accuracy: (0.2% + 1)
Resolution: 0.1 -
Capacitance
Range: 0.01nF to 9999F
Accuracy: (1% + 2)
Resolution: 0.01nF -
Frequency
Range: 0.5Hz to 199.99kHz
Accuracy: (0.005% + 1)
Resolution: 0.01Hz -
Duty Cycle
Range: 0.0% to 99.9%
Accuracy: (0.2% per kHz + 0.1%)
Resolution: 0.1% -
Temperature Measurement
Full range: 200C to 1090C (328F to 1994F)
With included probe: 40C to +260C
Accuracy: (2.2C or 2%) -
Conductance
Range: Up to 60.00nS
Accuracy: (1.0% + 10)
Resolution: 0.01nS -
Diode Test
Test voltage: Up to ~2V
Accuracy: (1% + 1)
Resolution: 0.001V
Display & Interface
-
Digital Display: 6000-count standard, 19,999-count high-resolution mode
-
Analog Bar Graph: 32 segments
-
Update Rates: Digital 4/sec; Bar graph 40/sec
-
Backlight: Two-level backlight with illuminated keypad
Mechanical & Environmental Features
-
Ingress Protection: IP67 (dustproof and waterproof)
-
Drop Test: Withstands drops from up to 4 meters
-
Housing: Rugged casing with integrated holster and lead storage
-
Battery Type: 3 AA alkaline
-
Battery Life: Approximately 800 hours (without backlight)
-
Operating Temperature: 15C to +55C (short-term down to 40C)
-
Storage Temperature: 40C to +60C
-
Humidity (non-condensing):
0%90% up to 35C
0%70% between 35C55C -
Altitude: Operates up to 2000m
Dimensions & Weight
-
Size (with holster): Approx. 21.5 10.1 6.0cm
-
Weight (with holster): Approx. 698.5g
Key Features
-
True-RMS measurements for accurate readings on non-linear loads
-
Low-pass filter for VFD (variable frequency drive) measurements
-
Built-in thermometer (with probe)
-
Peak capture (250s), Min/Max/Avg recording
-
Auto and manual ranging
-
Relative (REL) mode for zeroing
-
Touch Hold and standard data hold functions
-
Input Alert for incorrect jack usage
Summary Table
| Feature | Specification |
|---|---|
| DC Voltage | Up to 1000V (0.05%) |
| AC Voltage | Up to 1000V (0.7%) |
| DC Current | Up to 10A (0.2%) |
| AC Current | Up to 10A (1.0%) |
| Resistance | Up to 50M (0.2%) |
| Capacitance | Up to 9999F (1%) |
| Frequency | Up to 199.99kHz (0.005%) |
| Temperature | 200C to 1090C |
| Conductance | Up to 60.00nS |
| Diode Test | Up to ~2V |
| Display | 6000/19,999 counts with bar graph |
| Ruggedness | IP67, 4m drop-tested |
| Battery Life | ~800 hours (AA batteries) |
| Dimensions (cm) | 21.5 10.1 6.0 |
| Weight | ~698.5g |