Description
The Fenwal 35-605506-113 Direct Spark Ignition Control Module is used in gas-fired heating systems. It uses a direct spark ignition system which guarantees ignition with a 3 try system to ensure that the burnes are lit. The module includes a 30-second pre-purge to remove any gas before ignition and a 7-second trial for ignition to increase safety and performance. Running at 24V, this model is widely used in HVAC systems including residential furnaces and boilers. Advantages include increased combustion efficiency, reduced pollution and enhanced safety.